WECON PLC protocols

Supported series: LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM

HMI settings

Item

Settings

Note

Protocol

WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM

Connection

RS422/RS485

Baud rate

9600

Data bit

7

Parity

EVEN

Stop bit

1

PLC station No.

1

Address list

Type

Device registers

HMI registers

Format

Range

Note

Bit

X

X

X o

0~303237

0~303237

Y

Y

Y o

0~303237

M

M

M d

0~99999

T

T

T d

0~99999

C

C

C d

0~99999

S

S

S d

0~99999

Word

X

X

X o

0~303237

Y

Y

Y o

0~303237

M

M

M d

0~99999

T

T

T d

0~99999

C

C

C d

0~199

D

D

D d

0~7999

S

S

S d

0~99999

SD

SD

SD d

8000~9999

Cable wiring

  1. RS485

HMI serial port

Device port

COM1

COM2

COM3

RS485

1 RX+

1 RX+

7 RX+

A+

6 RX-

6 RX-

8 RX-

B-

5 GND

5 GND

5 GND

GND

  1. RS422

HMI serial port

Device port

RS485

COM1

1 TX+

2 RX+

6 TX-

1RX-

9 RX+

7 TX+

8 RX-

4 TX-

5 GND

3 SG

Note:

COM3 is available in 8000 series and advanced series.